Product
Menu

Heat Pumps


Our HEAT products are invented and developed by our team of engineers with over 10 years experiences in heating solutions industry. For decades, we have proudly provided heat pump system to numbers of satisfied clients, mostly factories and hotels, including Honda Automobile, Siam Aisin, Dusit Thani Hotel as our long-term clients. Our philosophy is to provide our clients the most efficient heating system with highest level durability attainable. Directory of HEAT product categories are as follows:

 

 

 

 

 

Air Source Heat Pumps


 


 

Model : Heat Plus

Maximum Hot Water 70 ºC R134a Cold Air
     Model : HEAT PLUS
     Selected model for the hotel and hospitality industry

     Features
       • Produce 50 ºC - 70 ºC hot water

             • Heating capacity 70kW - 2,000 kW

     Heat Sources
       • Ambient air with temperature range of 10 ºC - 40 ºC

             • Wasted hot air from heating process
             • Wasted hot air from machine cooling system

     Benefits
       • Efficiency in heat production increases to 400%

             • Save 50 - 70% on heating cost
             • Get free cold air as byproduct, when using ambient air as heat source
             • Reduce global warming

     Option
           
Heat pump can be use for bad water quality or water containing high levels of chloride with Titanium Heat Exchanger.

 

Model HEAT PLUS ZERO HEAT PLUS 1 HEAT PLUS 2 HEAT PLUS 3 HEAT PLUS 4 HEAT PLUS 5
Heating Capacity (kW.) 13.00 19.30 25.90 36.70 51.65 71.58

Cooling Capacity (kW.), (Btu/hr.)

9.95(34,000) 15.40(52,800) 21.10(72,342) 29.60(101,486) 40.10(137,485) 56.60(194,057)
Hot Water Flow Rate (Lph) 372 554 744 1,056 1,484 2,056
Water In Temperature(ºC) 30
Water Out Temperature(ºC) 60
Max Hot Water Outlet Temp.(ºC) 70
Air Flow Rate(m3/hr.),(cfm) 2,038(1,200) 3,400(2,000) 4,250(2,500) 6,800(4,000) 8,500(5,000) 12,750(7,500)
compressor (Type) Scroll
(Refrigeration) R-134a
Electrical(V/Ph/Hz) 400/3/50
Power at Recovery Rate Included all electrical parts(kW.) 3.31 4.72 5.95 8.96 12.50 17.20
RLA@Recovery Rate(Amp) 7.90 9.46 12.20 20.20 28.30 34.66
FLA(Amp) 980 14.30 17.60 22.35 31.20 42.80
Casing Material Stainless Steel
Dimension(WxDxH)mm. 680x540x1180 850x640x1570 1390x640x1570 1750x940x1750
Approximate Net Weight(Kg.) 135.0 206.0 245.0 312.0 420.0 720.0
Water Inlet / Outlet(inch) 1"/1" 1 1/4" / 1 1/4" 1 1/2" / 1 1/2"
Condensated Drain(inch) 393 409 435 410 413 416
Co2 Reduction(kgs./hr.) 1.09 1.72 2.51 3.28 4.68 6.55


          Note : 1. Specification subject to change without prior notice for product improvement.
                    2. Maximum operating air temperautre is 50ºC . Minimum operating air temperature is 10ºC.
                    3. Performance rated at ambient 35ºC DB., 26.5ºC WB.
                     4. Please contact HEAT for capacity at other rated conditions.
 

 

HEAT PLUS ZERO - Perfomance Curve

HEAT PLUS 1 - Perfomance Curve

HEAT PLUS 2 - Perfomance Curve

HEAT PLUS 3 - Perfomance Curve

HEAT PLUS 4 - Perfomance Curve

 

 

 

Water Source Heat Pumps


 

 

 

Hot Water 80 ºC R134a Cold Water 7 ºC
     Model : HEAT AQUA
     Newly designed for Industrial factory use for both hot and cold water.
 

     Feature
       • Produce 50 ºC - 80 ºC hot water
             • Heating capacity 70kW - 2,000kW

     Heat Sources
       • Natural water supply

             • Water in machine cooling system
             • Water used in A/C cooling system
             • Cold water returned from A/C system
             • Water required to be cooled down for feeding machine or process

     Benefits
       • Efficiency in heat production increases to 480%

             • Save 50 - 80% on heating cost
             • Reduce electricity cost on cooling system

  Commercial Building Industrial Factory
Model HEAT AQUA-50 HEAT AQUA-70 HEAT AQUA-65 HEAT AQUA-80 HEAT AQUA-100
Heating Capacity (kW.) 53.60 69.80 36.70 51.65 71.58

Cooling Capacity (kW.), (Btu/hr.)

39.00 50.60 43.30 56.80 66.00
Hot Water Flow Rate (Lph) 1,536 2,001 1,900 2,373 2,766
Water In Temperature(ºC) 30
Water Out Temperature(ºC) 60
Max Hot Water Outlet Temp.(ºC) 65 80
Chill Water Flow Rate(Lph) 6,707 8,702 7,790 9,768 11,350
Chill Water In Temperature(ºC) 12
Chill Water Out Temperature(ºC) 7
compressor (Type) Scroll Semi Hermatic Reciprocating
(Refrigeration) R-134a
Electrical(V/Ph/Hz) 400/3/50
Power at Recovery Rate Included all electrical parts(kW.) 16.00 21.10 19.80 24.80 29.20
RLA@Recovery Rate(Amp) 30.60 46.12 44.20 52.40 73.70
FLA(Amp) 37.20 54.10 52.60 60.80 87.20
Casing Material Electro-Galvanized Steel
Dimension(WxDxH)mm. 1250x850x1850 1530x1250x1850
Approximate Net Weight(Kg.) 480.0 660.0 740.0 830.0 920.0
Water Inlet / Outlet(inch) 1 1/2" / 1 1/2" 2"/2" 2 1/2" / 2 1/2"
Condensated Drain(inch) 579 572 563 557
Co2 Reduction(kgs./hr.) 10.13 13.02 12.01 15.00 17.30


          Note : 1. Specification subject to change without prior notice for product improvement.
                    2. Maximum operating air temperautre is 50ºC . Minimum operating air temperature is 10ºC.
                    3. Performance rated at ambient 35ºC DB., 26.5ºC WB.
                     4. Please contact HEAT for capacity at other rated conditions.
 

Performance Curve - Heating Efficiency